6
FREQUENCY
Function Sensitivity
(ACrms)
Range
mV 300mV 10Hz - 125kHz
5V 2V 10Hz - 125kHz
50V 20V 10Hz - 20kHz
500V 80V 10Hz - 1kHz
1000V 300V 10Hz - 1kHz
, Cx, diode
300mV 10Hz - 125kHz
µA, mA, A
10% F.S. 10Hz - 125kHz
Accuracy: 0.01% + 2d
Audible Continuity:
Measurement threshold: Beeper will sound if measurement is below
20. Beeper will not sound if measurement is above 200. Beeper
may or may not sound if measurement is between 20 and 200.
Response time: < 100µs
Accuracy Notes: Accuracy is ± (% reading digits + number of digits), or
as otherwise specified, at 23°C ±5°C < 75% R.H. True RMS accuracies
are specified from 5% to 100% of range or as otherwise specified.
Maximum Crest Factor <3:1 at full scale & <6:1 at half scale (with
frequency component within the specified frequency bandwidth for non-
sinusoidal waveforms).
Digital Display: 5000-count LCD display; 5 per second nominal
refresh rate
Bar Graph Display: 52-segment bargraph; 60 per second nominal
refresh rate
Low Battery: Below approx. 7V
Operating Temperature: 41° to 104°F (5° to 40°C)
Storage Temperature: -4° to 140°F (-20 to 60
o
C
Relative Humidity: Max 80% up to 87ºF (31ºC) decreasing linearly
to 50% at 104ºF(40ºC): <80% storage
Altitude: Operating below 2000 meters
Temp. Coefficient: Nominal 0.15 x specified accuracy per ºC
(between 0 and 18
o
C or 28 to 50
o
C), or as
otherwise specified
Power Supply: 9V battery (NEDA1604, JIS006P or IEC6F22)